Warranty: | 10 Years |
---|---|
Accuracy: | High |
Main Application: | Water, Liquids and Liquid-Solid Two-Phase Liquids |
Size: | 15-800mm |
Sensor: | Tube/Flange |
Application: | Industrial Production |
Customization: |
---|
Suppliers with verified business licenses
Feature
*Widely used to measure the volume flow rate of conductive liquids and liquid-solid two-phase liquids, there are no movable or throttling components inside tube, so almost no pressure loss and blockage, especially suitable for situations where the pressure in the process pipeline is not high or liquids relies on gravity flow.
*Widely used in industrials such as chemical engineering, chemical fiber, food, paper making, sugar making, mining, water supply and drainage, environmental protection, water conservancy, steel, petrochemicals, oil fields, and pharmaceuticals, can measure volume flow rate of conductive fluid media such as acids, alkalis, salt solutions, slurries, mineral slurries, coal water slurries, corn slurry, fiber slurry, syrup, lime slurry, sewage, cooling water, brine, hydrogen peroxide, beer, wort, various beverages, black liquid, green liquid, medicinal liquid, etc.
*Good stability, anti-interference ability and interchangeability, integrated structure with good moisture-proof and waterproof performance, suitable for underground or humid environment installation, The sensor has automatic calibration function and nonlinear correction function, can be set with parameters through serial port.
*Other diameters and pressure levels can be customized according to customer requirements.
Electrode Material | Corrosion Resistance and Applicability |
Mo-bearing Stainless Steels | Suitable for nitric acid, concentration <5% sulfuric acid at room temperature, boiling phosphoric acid, formic acid, alkali solution; strong corrosion resistance for such as sulfite, seawater, and ester acid under certain pressure, widely used in industries such as petrochemical, urea, and vinylon. |
Hastelloy B (HB) | It has corrosion resistance in non oxidizing environments, suitable for fluoric acid, but not suitable for oxidizing acids such as nitric acid, It can be used to measure seawater, weak acids, and weak bases. |
Hastelloy C (HC) | It has corrosion resistance in moderate oxidizing and reducing environments, suitable for measuring various organic acids, alkaline media, fluorides, chlorides, such as acetaldehyde, acid, sodium hydroxide, etc |
Titanium | Resistant to seawater corrosion, including various chlorides and hypochlorites, oxidizing acids (excluding fuming nitric acid), organic acids, alkalis, and other solutions. Not resistant to pure reducing acids (such as sulfuric acid) corrosion, but when acid contains oxidants (such as nitric acid, FE+++, Cu++), the corrosiveness is greatly reduced. Zinc chloride, potassium chloride, calcium chloride, frozen salt water, seawater, ammonia, etc. can be measured. |
Tantalum | Excellent corrosion resistance (similar to glass), it can withstand almost all chemical media (including boiling point hydrochloric acid, nitric acid, and sulfuric acid below 175 ºC) except for fuming sulfuric acid, and alkali, can measure concentrated hydrochloric acid, nitric acid, sulfuric acid, aqua regia, and other solutions. |
Platinum | It has good corrosion resistance to various acids, alkali and various salts, but is not resistant to aqua regia corrosion. |
Lining Material | Performance | Application |
PTEF | 1. Plastic with the most stable chemical properties, resistant to boiling hydrochloric acid, sulfuric acid, nitric acid, and aqua regia corrosion, as well as strong alkali and various organic solvents corrosion. 2. Poor wear resistance and bonding performance. |
1. -40 ºC~+180 ºC 2. Strong corrosive media such as concentrated acid and alkali 3. Sanitary media |
Neoprene Rubber | 1. It has excellent elasticity, high tensile strength, and good wear resistance. 2. It is resistant to corrosion in low concentration acid, alkali, and salt media; not resistant to corrosion in oxidizing media. |
1.<65 ºC 2. Measure general water, sewage, mud, and mineral slurry |
Polyurethane Rubber | 1. excellent wear resistance (10 times of natural rubber). 2. Poor acid and alkaline resistance. |
1.<65 ºC 2. Neutral and strongly worn mineral slurry, coal slurry, and slurry |
Acid resistant Rubber | Resistant to corrosion at room temperature by hydrochloric acid, acetic acid, oxalic acid, ammonia, phosphoric acid, and 50% sulfuric acid, potassium hydroxide, avoiding strong oxidants. | 1.<25 ºC~+90 ºC 2. General acid, alkali, and salt solutions |
Integrated Meter Size | |||||||||
Diameter(mm) | Pressure(MPa) | Size(mm) | Flange Connection Size(mm) | ||||||
Height | End Face Length | e | Flange Outer Diameter | Hole Position Diameter | Hole Diameter | NO. of Hole | Flange Thickness | ||
15 | 4 | 290 | 150 | 95 | 65 | 14 | 4 | 16 | |
25 | 300 | 150 | 115 | 85 | 14 | 4 | 18 | ||
50 | 330 | 200 | 165 | 125 | 18 | 4 | 20 | ||
100 | 1.6 | 385 | 250 | 220 | 180 | 18 | 8 | 20 | |
150 | 430 | 300 | 285 | 240 | 22 | 8 | 22 | ||
200 | 1 | 480 | 350 | 340 | 295 | 22 | 8 | 24 | |
250 | 580 | 400 | 395 | 350 | 22 | 12 | 25 | ||
300 | 620 | 500 | 445 | 400 | 22 | 12 | 25 | ||
350 | 730 | 500 | 400 | 505 | 460 | 22 | 16 | 26 | |
400 | 800 | 600 | 400 | 565 | 515 | 26 | 16 | 26 | |
500 | 900 | 600 | 400 | 670 | 620 | 26 | 20 | 28 | |
600 | 1020 | 600 | 400 | 780 | 725 | 30 | 20 | 28 | |
700 | 1080 | 700 | 450 | 895 | 840 | 30 | 24 | 30 | |
800 | 1230 | 800 | 500 | 1015 | 950 | 33 | 24 | 30 |
Clip Meter Size | |||||||
Diameter | 25 | 40 | 50 | 80 | 100 | 150 | 200 |
Pressure | 2.5 | 1.6 | |||||
Height | 300 | 315 | 330 | 360 | 385 | 430 | 480 |
End face Distance | 95 | 110 | 120 | 120 | 180 | 230 | 300 |
Outside Diameter | 67 | 85 | 100 | 100 | 155 | 200 | 250 |
Suppliers with verified business licenses